D-50W series normal dual switching power supply
Features:
·AC input voltage range selected by switch
·Small volume,low weight,high efficiency
·Protections:short circuit/over load
·LED indicator for power on
·100% full load burn-in test
·2 Years warranty
Model |
D-50A |
D-50B |
D-50C |
|||||
output |
DC voltage |
CH1:5V |
CH2:12V |
CH1:5V |
CH2:24V |
CH1:12V |
CH2:24V |
|
Voltage tolerance |
±2% |
+4%~-8% |
±3% |
+6%~-8% |
±3% |
+6%~-8% |
||
Rated current |
6A |
2A |
4A |
1.5A |
2A |
1.2A |
||
Current range |
0.8~6A |
0.3~2A |
0.8~4A |
0.2~1.5A |
0.5~2A |
0.2~1.2A |
||
Rated power |
54W |
56W |
52.8W |
|||||
Ripple&noise |
80mvp-p |
100mvp-p |
80mvp-p |
120mvp-p |
100mvp-p |
120mvp-p |
||
DCvoltage ADJ.range |
CH1:-9%~+10% |
|||||||
input |
Voltage range |
90~132VAC/180~264VAC(selected by switch),255~373VDC |
||||||
frequency |
47~63HZ |
|||||||
AC current |
1.3A/115VAC,0.65A/230VAC |
|||||||
efficiency |
73% |
75% |
77% |
|||||
Inrush current |
Cold start current18A/115VAC,36A/230VAC |
|||||||
Leakage current |
< 2mA/240VAC |
|||||||
protection |
overload |
Rated output power110%~150start over load protection |
||||||
protection type :part layer type current limit,auto-recovery after fault condition is removed |
||||||||
----- |
----- |
|||||||
----- |
||||||||
environment |
Working temp,humidity |
-10℃~+60℃,20%~90%RH |
||||||
Storage temp,humidity |
-20℃~+85℃,10%~95%RH non-condensing |
|||||||
Withstand vibration |
10~500HZ,2G10min/1cycle,period for 60 minutes,each axes |
|||||||
safety |
Withstand voltage |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
||||||
Isolation resistance |
I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC |
|||||||
Fit standard |
Safety standard |
Compliance to UL1012 |
||||||
EMC standard |
Compliance to EN55022,CLASSA |
|||||||
others |
Dimension |
159*97*38mm(L*W*H) |
||||||
Weight/packing |
0.52kg/45pcs/24kg/0.041m³/1.45CUFT |
|||||||
note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25℃of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |
|||||||
如果您有任何关于合作的报价或有任何查询,请随时给我们发电子邮件 info@hwele.net或使用下面的查询表格。我们的销售代表将在24小时内与您联系。感谢您对我们的产品感兴趣。