DR-75W series Din-rail power supply
Features:
·universalACinputrange
·Small volume,low weight,high efficiency
·Protections:short circuit/over load/over voltage
·cooling by free air convection
·can be installed onDINrail:TS-35/7.5or TS-35/15
·LED indicator for power on
·100% full load burn-in test
·2 Years warranty
Model |
DR-75-12 |
DR-75-24 |
DR-75-48 |
|
output |
DC voltage |
12V |
24V |
48V |
Voltage tolerance |
±2% |
±1% |
±1% |
|
Rated current |
6.3A |
3.2A |
1.6A |
|
Current range |
0~6.3A |
0~3.2A |
0~1.6A |
|
Rated power |
76W |
76.8W |
76.8W |
|
Ripple&noise |
100mvp-p |
150mvp-p |
200mvp-p |
|
DCvoltage ADJ.range |
-9%~+10% |
±10% |
±10% |
|
input |
Voltage range |
90~264VAC,127~373VDC |
||
frequency |
47~63HZ |
|||
AC current |
1.6A/110VAC,0.96A/220VAC |
|||
efficiency |
79% |
81% |
84% |
|
Inrush current |
Cold start current 20A/115VAC,40A/230VAC |
|||
Leakage current |
< 1mA/240VAC |
|||
protection |
Over load |
Rated output power110%~150% start over load protection |
||
protection type :rated current limit,auto-recovery after fault condition is removed |
||||
over voltage |
15.6~17.8V |
30.6~33.2V |
54.8~56.6V |
|
protection type:cutoff output,recovery after restart power |
||||
environment |
Working temp,humidity |
-20℃~+60℃,20%~90%RH |
||
Storage temp,humidity |
-40℃~+85℃,10%~95%RH non-condensing |
|||
Withstand vibration |
10~500HZ,2G10min/1cycle,period for 60 minutes,each axes |
|||
safety |
Withstand voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
||
Isolation resistance |
I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC |
|||
Fit standard |
Safety standard |
Compliance to UL1012 |
||
EMC standard |
Compliance to EN55022,CLASSA |
|||
others |
Dimension |
55.5*125.2*100mm(L*W*H) |
||
Weight/packing |
0.6kg/20pcs/13kg/0.046m³/1.64CUFT |
|||
note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25℃of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |
如果您有任何关于合作的报价或有任何查询,请随时给我们发电子邮件 info@hwele.net或使用下面的查询表格。我们的销售代表将在24小时内与您联系。感谢您对我们的产品感兴趣。