【上一个产品】 | 【下一个产品】 |
LRS-350W series Ultra thin single switching power supply
Features:
·AC input range selected by switch(115/230)
·Withstand 300VAC surge input for 5 second
·Miniature size and 1U low profile,low weight
·Protections:Short circuit/Overload/Over voltage/Over temperature
·Forced air cooling by built-in DC fan
·Built-in cooling fan ON-OFF control
·No load power consumption<0.75W
·Operating altitude up to 5000 meters(Note6)
·LED indicator for power on
·100% full load burn-in test
·High efficiency,long life and high reliability
·3 years warranty
Model |
LRS-350-5 |
LRS-350-12 |
LRS-350-15 |
LRS-350-24 |
LRS-350-36 |
LRS-350-48 |
|
output |
DC voltage |
5V |
12V |
15V |
24V |
36V |
48V |
Rated current |
60A |
29A |
23.2A |
14.6A |
9.7A |
7.3A |
|
Current range |
0~60A |
0~29A |
0~23.2A |
0~14.6A |
0~9.7A |
0~7.3A |
|
Rated power |
300W |
348W |
348W |
350.4W |
349.2W |
350.4W |
|
Ripple&noise |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
200mVp-p |
200mVp-p |
|
DC voltage ADJ. range |
±10% |
±10% |
±10% |
±10% |
±10% |
±10% |
|
Voltage toleranceNote.3 |
±3% |
±2% |
±1% |
±1% |
±1% |
±1% |
|
Line regulationNote.4 |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
Load regulationNote.5 |
±2% |
±1% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
Setup,rise,hold up time |
800ms,50ms,16ms/230VAC(full load) |
||||||
input |
Voltage range |
90~132VAC/180~264VAC(selected by switch),240~373VDC |
|||||
Frequency range |
47~63HZ |
||||||
AC current |
6.8A/115VAC 3.4A/230VAC |
||||||
Inrush current |
Cold start 55A/230VAC |
||||||
Efficiency |
83% |
85% |
86% |
88% |
88% |
89% |
|
Leakage current |
<2mA/240VAC |
||||||
protection |
overload |
Rated output power110%~140% start over load protection |
|||||
protection type:hiccup mode,auto-recovery after fault condition is removed |
|||||||
Over voltage |
Rated output voltage 115%~135% Start over voltage protection |
||||||
Protection type:hiccup mode,auto-recovery after fault condition is removed |
|||||||
Over temperature |
100℃±10℃(RTH3 detect beside magnetic core) |
||||||
Protection type:cut off the output,auto-recovery after the temperature become normal |
|||||||
Function |
Fan ON-OFF control |
RTH3≥50℃Fan ON,≤40℃Fan OFF |
|||||
environment |
Working temp,humidity |
-25℃~+70℃(Please
refer to“derating
curve”) |
|||||
Storage temp,humidity |
-40℃~+85℃,10%~95%RH non-condensing |
||||||
Withstand vibration |
10~500HZ,2G10min/1cycle,period for 60 minutes,each axes |
||||||
safety |
Withstand voltage |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC |
|||||
Isolation resistance |
I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC |
||||||
Fit standard |
Safety standards |
Compliance to UL60950-1,TUV EN60950-1,GB4943 |
|||||
EMC emission |
Compliance to EN55022(CISPR22)Class B,GB9254 Class B,EN55014,EN61000-3-2,3 |
||||||
EMC immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61000-6-1 |
||||||
others |
Dimension |
215*115*30mm(L*W*H) |
|||||
Weight/packing |
0.76kg/20pcs/16.2kg/0.024m³/0.85CUFT |
||||||
MTBF |
≥295K hrs min. MIL-HDBK-217F(25℃) |
||||||
note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4.Line regulation is measured from low line to high line at rated load. 5.Load regulation is measured from 0% to 100% rated load 6.The ambient temperature derating of 5℃/1000 m is needed for operating altitude greater than 2000m(6500ft) 7.The power supply is considered as a component which will be installed into a finalequipment.The final equipment must be re-confirmed that it still meets EMC directives.For guidance on how to perform these EMC tests. |
如果您有任何关于合作的报价或有任何查询,请随时给我们发电子邮件 info@hwele.net或使用下面的查询表格。我们的销售代表将在24小时内与您联系。感谢您对我们的产品感兴趣。