HS-75W series compact single switching power supply
Features:
·AC input voltage range selected by switch
·Small volume,low weight,high efficiency
·Protections:short circuit/over load
·cooling by free air convection
·LED indicator for power on
·100% full load burn-in test
·2 Years warranty
Model |
HS-75-5 |
HS-75-12 |
HS-75-15 |
HS-75-24 |
|
output |
DC voltage |
5V |
12V |
15V |
24V |
Voltage tolerance |
±2% |
±1% |
±1% |
±1% |
|
Rated current |
10A |
6.3A |
5A |
3.2A |
|
Current range |
0~10A |
0~6.3A |
0~5A |
0~3.2A |
|
Rated power |
50W |
75.6W |
75W |
76.8W |
|
Ripple&noise |
80mvp-p |
120mvp-p |
120mvp-p |
120mvp-p |
|
DCvoltage ADJ.range |
-9%~+10% |
±10% |
±10% |
±10% |
|
input |
Voltage range |
90~132VAC/170~264VAC(selected by switch),235~373VDC |
|||
frequency |
47~63HZ |
||||
AC current |
1.8A/115VAC,0.9A/230VAC |
||||
efficiency |
80% |
82% |
82% |
84% |
|
Inrush current |
Cold start current18A/115VAC,36A/230VAC |
||||
Leakage current |
< 1mA/240VAC |
||||
protection |
overload |
Rated output power105%~135% start over load protection |
|||
protection type:hiccup mode,auto-recovery after fault condition is removed |
|||||
----- |
----- |
||||
----- |
|||||
environment |
Working temp,humidity |
-10℃~+60℃,20%~90%RH |
|||
Storage temp,humidity |
-20℃~+85℃,10%~95%RH non-condensing |
||||
Withstand vibration |
10~500HZ,2G10min/1cycle,period for 60 minutes,each axes |
||||
safety |
Withstand voltage |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
|||
Isolation resistance |
I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC |
||||
Fit standard |
Safety standard |
Compliance to UL1012 |
|||
EMC standard |
Compliance to EN55022,CLASSA |
||||
others |
Dimension |
111*78*36mm(L*W*H) |
|||
Weight/packing |
0.3kg/50pcs/16kg/0.027 m³/0.96CUFT |
||||
note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25℃of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |
如果您有任何关于合作的报价或有任何查询,请随时给我们发电子邮件 info@hwele.net或使用下面的查询表格。我们的销售代表将在24小时内与您联系。感谢您对我们的产品感兴趣。