【Prev Products】 | 【Next Products】 |
NES-75W series Efficient single switching power supply
Features:
·universal AC inputrange
·Small volume,low weight,high efficiency
·Protections:short circuit/over load/over voltage
·cooling by free air convection
·LED indicator for power on
·100% full load burn-in test
·2 Years warranty
Model |
NES-75-5 |
NES-75-12 |
NES-75-15 |
NES-75-24 |
||||
output |
DC voltage |
5V |
12V |
15V |
24V |
|||
Voltage tolerance |
±2% |
±1% |
±1% |
±1% |
||||
Rated current |
15A |
6.3A |
5A |
3.2A |
||||
Current range |
0~10A |
0~6.3A |
0~5A |
0~3.2A |
||||
Rated power |
75W |
75.6W |
75W |
76.8W |
||||
Ripple&noise |
80mvp-p |
100mvp-p |
100mvp-p |
120mvp-p |
||||
DCvoltage ADJ.range |
-9%~+10% |
±10% |
±10% |
±10% |
||||
input |
Voltage range |
90~264VAC,125~373VDC |
||||||
frequency |
47~63HZ |
|||||||
AC current |
1.5A/115VAC,0.75A/230VAC |
|||||||
efficiency |
79% |
82% |
82% |
84% |
||||
Inrush current |
Cold start current 20A/115VAC,40A/230VAC |
|||||||
Leakage current |
< 3.5mA/240VAC |
|||||||
protection |
Over load |
Rated output power110%~150% start over load protection |
||||||
protection type:hiccup mode,auto-recovery after fault condition is removed |
||||||||
over voltage |
6.8~8.2V |
15.6~17.8V |
18.6~20.8V |
30.6~33.2V |
||||
protection type:hiccup mode,auto-recovery after fault condition is removed |
||||||||
environment |
Working temp,humidity |
-20℃~+60℃,20%~90%RH |
||||||
Storagetemp,humidity |
-40℃~+85℃,10%~95%RH non-condensing |
|||||||
Withstand vibration |
10~500HZ,2G10min/1cycle,period for 60 minutes,each axes |
|||||||
safety |
Withstand voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
||||||
Isolated resistance |
I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC |
|||||||
Fitstandard |
Safety standard |
Compliance to UL1012 |
||||||
EMC standard |
Compliance to EN55022,CLASSA |
|||||||
others |
Dimension |
129*98*38mm(L*W*H) |
||||||
Weight/packing |
0.4kg/45pcs/19kg/0.034m³/1.2CUFT |
|||||||
note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25℃of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |
|||||||
If you have any enquiry about quotation or cooperation,please feel free to email us at sales@hwele.net or use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.