【Prev Products】 | 【Next Products】 |
US-60W series slim type single switching power supply
Features:
·Universal AC input range
·Slim type,Small volume,low weight,high efficiency
·Protections:short circuit/over load
·Cooling by free air convection
·LED indicator for power on
·100% full load burn-in test
·No load consumption<0.8W
·2 Years warranty
Model |
US-60-12 |
US-60-24 |
|
|
output |
DC voltage |
12V |
24V |
|
Voltage tolerance |
±2% |
±2% |
|
|
Rated current |
5A |
2.5A |
|
|
Current range |
0~5A |
0~2.5A |
|
|
Rated power |
60W |
60W |
|
|
Ripple&noise |
150mvp-p |
180mvp-p |
|
|
DCvoltage ADJ.range |
±10% |
±10% |
|
|
input |
Voltage range |
90-264VAC,135~373VDC |
||
Setup,rise,hold up time |
800ms,30ms,20ms/230VAC,1200ms,30ms,20ms/115VAC |
|||
frequency |
47~63HZ |
|||
AC current |
1.2A/115VAC 0.60A/230VAC |
|||
efficiency |
86% |
87% |
|
|
Inrush current |
Cold start current 45A/230VAC |
|||
Leakage current |
< 1mA/240VAC |
|||
protection |
overload |
Rated output power110%~150% start over load protection |
||
protection type:hiccup mode,auto-recovery after fault condition is removed |
||||
|
|
|||
|
||||
|
|
|||
|
||||
environment |
Working temp,humidity |
-20℃~+50℃,20%~90%RH |
||
Storage temp,humidity |
-40℃~+85℃,10%~95%RH non-condensing |
|||
Withstand vibration |
10~500HZ,2G10min/1cycle,period for 60 minutes,each axes |
|||
safety |
Withstand voltage |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
||
Isolation resistance |
I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC |
|||
Fit standard |
Safety standard |
Compliance to UL1012,UL60950-1,GB4943 |
||
EMC standard |
Compliance to EN55022,EN61000-3-2,CLASSA |
|||
others |
Dimension |
167*48*28mm (L*W*H) |
||
Weight/packing |
0.3kg/60pcs/17.8kg/0.025m³/0.88CUFT |
|||
MTBF |
330K hrs min. MIL-HDBK-217F(25℃) |
|||
note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25℃of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |
If you have any enquiry about quotation or cooperation,please feel free to email us at sales@hwele.net or use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.