【Prev Products】 | 【Next Products】 |
HPV-200W series PFC Constant Voltage LED driver
Features:·universal AC input
·BUilt-in power factor correction
·Protections:short circuit/over load/over voltage/over temp
·Cooling by free air convection
·IP67 design for indoor or outdoor installations
·Suitble for LED lighting and moving sign applications
·3Year warranty
Model |
HPV-200-12 |
HPV-200-24 |
HPV-200-36 |
HPV-200-42 |
HPV-200-48 |
HPV-200-54 |
|
output |
DC voltage |
12V |
24V |
36V |
42V |
48V |
54V |
Rated current |
16.5A |
8.5A |
5.6A |
4.77A |
4.17A |
3.71A |
|
Rated power |
198W |
204W |
201.6W |
200.3W |
200.1W |
200.3W |
|
Ripple&noise |
150mvp-p |
150mvp-p |
150mvp-p |
200mvp-p |
200mvp-p |
200mvp-p |
|
Voltage tolerance |
±2.5% |
±1% |
±1% |
±1% |
±1% |
±1% |
|
input |
Voltage range |
90~264VAC,47~63HZ ,127~370VDC |
|||||
AC current |
3.2A/115VAC,1.6A/230VAC |
||||||
Power factor |
PF>0.95/230VAC,PF>0.98/115VAC Start overload protection |
||||||
efficiency |
90% |
92% |
93% |
93% |
93.5% |
94% |
|
Inrush current |
Cold start current35A/115VAC,75A/230VAC |
||||||
Leakage current |
< 0.75mA/240VAC |
||||||
protection |
Over load |
95%~108% |
|||||
protection type :Constant current limiting ,auto-recovery after fault condition is removed |
|||||||
Short circuit |
Hiccup mode,recovers automatically after fault condition is remove |
||||||
Over voltage |
14~17V |
26~33V |
40~48V |
46~50V |
53~62V |
59~65V |
|
protection type:Shut down o/p voltage re-power on to recover |
|||||||
Over temperature |
105℃±10℃(RTH2) |
||||||
protection type:Shut down o/p voltage re-power on to recover |
|||||||
environment |
Working temp,humidity |
-30℃~+60℃,20%~90%RH |
|||||
Storagetemp,humidity |
-40℃~+85℃,10%~95%RH non-condensing |
||||||
Withstand vibration |
10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes |
||||||
safety |
Withstand voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
|||||
Isolated resistance |
I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC |
||||||
Fitstandard |
Safety standard |
Fit UL1310 CLASS2,TUV EN61347-1,EN61347-2-13, IP65approved |
|||||
EMC standard |
Fit EN55015,EN61000-3-2ClassC(>60%load):EN61000-3-3 |
||||||
others |
Dimension |
249*69*39mm(L*W*H) |
|||||
Weight/packing |
1.3kg/20pcs/27kg/0.033m³/1.15CUFT |
||||||
note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25℃of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |
If you have any enquiry about quotation or cooperation,please feel free to email us at sales@hwele.net or use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.