【Prev Products】 | 【Next Products】 |
T-120W series normal triple switching power supply
Features:
·AC input voltage range selected by switch
·Small volume,low weight,high efficiency
·Protections:short circuit/over load/over voltage
·LED indicator for power on
·100% full load burn-in test
·2 Years warranty
Model |
T-120A |
T-120B |
||||||
output |
DC voltage |
CH1:+5V |
CH2:+12V |
CH3:-5V |
CH1:+5V |
CH2:+12V |
CH3:-12V |
|
Voltage tolerance |
±2% |
±6% |
±6% |
±2% |
±6% |
±6% |
||
Rated current |
11A |
5A |
1A |
11A |
4.5A |
1A |
||
Current range |
2~11A |
0.5~5A |
0.2~1A |
2~11A |
0.5~4.5A |
0.2~1A |
||
Rated power |
120W |
121W |
||||||
Ripple&noise |
80mvp-p |
120mvp-p |
80mvp-p |
80mvp-p |
120mvp-p |
120mvp-p |
||
DCvoltage ADJ.range |
CH1:-9%~+10% |
|||||||
input |
Voltage range |
90~132VAC/180~264VAC(selected by switch),255~373VDC |
||||||
frequency |
47~63HZ |
|||||||
AC current |
2.8A/115VAC,1.6A/230VAC |
|||||||
efficiency |
77% |
77% |
||||||
Inrush current |
Cold start current 30A/115VAC,60A/230VAC |
|||||||
Leakage current |
< 3.5mA/240VAC |
|||||||
protection |
overload |
Rated output power110%~150start over load protection |
||||||
protection type:cutoff output,recovery after restart power |
||||||||
over voltage |
CH1、CH2:115~135% |
|||||||
protection type:cutoff output,recovery after restart power |
||||||||
environment |
Working temp,humidity |
-10℃~+60℃,20%~90%RH |
||||||
Storagetemp,humidity |
-20℃~+85℃,10%~95%RH non-condensing |
|||||||
Withstand vibration |
10~500HZ,2G10min/1cycle,period for 60 minutes,each axes |
|||||||
safety |
Withstand voltage |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
||||||
Isolation resistance |
I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC |
|||||||
Fitstandard |
Safety standard |
Compliance toUL1012 |
||||||
EMC standard |
Compliance toEN55022,CLASSA |
|||||||
others |
Dimension |
199*110*50mm(L*W*H) |
||||||
Weight/packing |
0.85kg/24pcs/21.5kg/0.043m³/1.51CUFT |
|||||||
note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |
|||||||
If you have any enquiry about quotation or cooperation,please feel free to email us at sales@hwele.net or use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.